    Brand Name : MORNSUN
    Model Number : LOF750-20Bxx Series
    Certification : CE/UL/CB
    Price : Negotiated
    Payment Terms : T/T
    Supply Ability : 500Kpcs/month
    Delivery Time : Negotiated
    • Product Details
    • Company Profile

    750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment

    750W AC DC Open Frame Switching Power Supply with PFC function single output


    Descriptions


    LOF750-20Bx series is one of Mornsun’s AC-DC miniaturize open frame power supply and suitable for all kinds of BF type(be accessible to patients) medical system equipment.It features universal AC input and at the same time accepts DC input voltage,cost-effective,low no load power consumption,high efficiency,high reliability and double or reinforced insulation.These converters offer excellent EMC performance and meet IEC/EN/UL62368,GB4943,IEC/EN60335,IEC/EN61558,IEC/EN/ES60601-1standards and they are widely used in areas of Medical, LED, street light control,electricity,security,telecommunications LED, smart home etc.


    Features

    • Universal 90 - 264VAC or 127 - 370VDC input voltage
    • Compact size 5”× 3”
    • Operating ambient temperature range: -40C to +70C
    • Built-in active PFC function
    • Operating altitude up to 5000m
    • Output short circuit, over-current, over-voltage,
    • over-temperature protection
    • 450W with air cooling, 750W with 25CFM
    • 5VDC standby output, 5VDC fan supply
    • PG signal and remote sensing function
    • Design to meet medical approvals and be suitable for
    • BF type applications
    • The base plate with conformal coating
    • Safety according to IEC/EN62368, ES/EN60601, EN60335,GB4943

    Specifications


    Selection Guide
    CertificationPart No.Cooling Method

    Input Voltage

    Range

    (V)

    Output

    Power

    (W)*

    Nominal Output

    Voltage and Current (Vo/Io)

    Output

    Adjustable

    Range ADJ (V)

    Efficiency at

    230VAC (%)

    Typ. *

    Capacitive

    Load

    (µF) Max.


    --

    LOF750-20B12Air coolingFull voltage range399.612V/33.31 1.4- 12.6925000
    25CFM699.612V/58.3
    LOF750-20B15Air coolingFull voltage range400.515V/26.714.25- 15.75925000
    25CFM700.515V/46.7

    LOF750-20B24

    Air cooling1 15VAC400.824V/ 16.7

    22.8-25.2


    94


    3000

    230VAC451.224V/ 18.8
    25CFMFull voltage range748.824V/31.2

    LOF750-20B27

    Air cooling1 15VAC399.627V/ 14.8

    25.65-28.35


    94


    3000

    230VAC450.927V/ 16.7
    25CFMFull voltage range750.627V/27.8

    LOF750-20B36

    Air cooling1 15VAC399.636V/ 1 1. 1

    34.2-37.8


    94.5


    2000

    230VAC450.036V/ 12.5
    25CFMFull voltage range748.836V/20.8

    LOF750-20B48

    Air cooling1 15VAC398.448V/8.3

    45.6-50.4


    95


    2000

    230VAC451.248V/9.4
    25CFMFull voltage range748.848V/ 15.6

    LOF750-20B54

    Air cooling1 15VAC399.654V/7.4

    51.3-56.7


    95


    1000

    230VAC449.854V/8.33
    25CFMFull voltage range750.054V/ 13.89
    Notes: 1.*Under any conditions, the total power of the product should not exceed the rated power. When the output voltage is increased, the total output power cannot exceed the rated output power, when the output voltage is decreased, the output current cannot exceed the rated output current; 2.*When measuring the full load efficiency, the fan should be connected to an external power supply. Fan loss is not included in the input power.

    Input Specifications
    ItemOperating ConditionsMin.Typ.Max.Unit
    Input Voltage RangeAC input90--264VAC
    DC input127--370VDC
    Input Frequency47--63Hz
    Input Current1 15VAC----8

    A

    230VAC----4
    Inrush Current1 15VACCold start--50--
    230VAC--80--
    Power Factor1 15VACFull load0.98------
    230VAC0.95----
    Leakage Current264VACContact leakage current<0. 1mA
    Earth leakage current<0.5mA
    Hot PlugUnavailable
    Output Specifications*
    ItemOperating ConditionsMin.Typ.Max.Unit

    Output Voltage

    Accuracy*

    Full load12V/ 15V/24V/27V--±2.0--

    %

    36V/48V/54V--± 1.0--
    Line RegulationRated load--±0.5--
    Load Regulation0%- 100% load--± 1.0--
    Ripple & Noise*20MHz band width (peak-to-peak value)----200750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment V

    Temperature

    Coefficient

    --±0.03--%/C
    Minimum Load0----%
    Hold-up Time25C, 115VAC/230VAC10----ms

    Stand-by Power

    Consumption

    Room temperature, 230VAC input

    (PS_ON Low and 5Vsb without load (including fan))

    ----0.5W
    Short Circuit Protection

    Recovery time <5s after the short

    circuit disappear

    Hiccup, continuous, self-recover

    Over-current

    Protection

    ≥105%Io, hiccup, self-recover

    Over-voltage

    Protection

    12V≤15.6V

    Output voltage turn off, re-power on for recover

    15V≤19.5V
    24V≤31.2V
    27V≤35. 1V
    36V≤46.8V
    48V≤60.0V
    54V≤64.0V

    Over-temperature

    Protection

    Protection when over-temperature, recover automatically after the temperature drops
    Fan Power *The 5Vsb serves as the standby power supply and also supplies power to the fan, the maximum output current of the fan and 5Vsb is 2A
    PS_ON Input Signal*Power onPS_ON High2--5V
    Power offPS_ON Low0--0.6

    PG Signal*

    Power on

    The PG signal goes high

    with 10ms to 500ms delay

    after power set up

    10

    --

    500

    ms

    Power off/Power fail

    The TTL signal goes low at

    least 1ms before output

    below 90% of rated value

    1

    --


    --

    High levelHigh2--6V
    Low levelLow0--0.6
    General Specifications
    ItemOperating ConditionsMin.Typ.Max.Unit

    Isolation

    Test

    Input - output

    Electric strength test for 1min,

    leakage current <10mA

    4000----

    VAC

    Input - 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment2000----
    Output - 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment1500----

    Insulation

    Resistanc

    e

    Input - output

    Environment temperature: 25±5C

    Relative humidity: <95%RH, non-condensing

    Testing voltage: 500VDC

    100----

    MQ

    Input - 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment100----
    Output - 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment100----

    Isolation

    level

    Input - output2 × MOPP
    Input - 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment1 × MOPP
    Output - 750W PFC SMPS AC DC Open Frame Power Supply Single Output For BF Medical Equipment1 × MOPP
    Operating Temperature-40--+70C
    Storage Temperature-40--+85
    Storage HumidityNon-condensing10--95%RH
    Operating Humidity20--90

    Power Derating


    Operating temperature derating

    25CFM12V/ 15V(700W)+50C to +70C2.0----%/C

    24V/27V/36V/

    48V/54V(750W)

    +50C to +70C2.0----

    Air cooling

    12V/ 15V(400W)+45C to +70C7.9----

    W/C

    24V/27V/ 36V/48V/

    54V

    (450W)

    90- 175VAC

    (400W)

    +45C to +70C7.0----

    176-264VAC

    (450W)

    +45C to +70C9.0----

    Input voltage

    derating

    90VAC - 1 15VAC0.8----%/VAC
    127VDC - 162VDC0.57----%/VDC
    Safety Standard

    Design refer to IEC/EN62368- 1, ES/EN60601- 1, EN60335- 1,

    GB4943. 1

    Safety ClassCLASS I/CLASS II
    MTBFMIL-HDBK-217F@25C>200,000 h
    Mechanical Specifications
    Case MaterialOpen frame
    Dimension127.0mm × 76.2mm × 43.0 mm
    Weight625g (Typ.)
    Cooling Method*Air cooling(400W/450W) / 25CFM (700W/750W)
    Note: *Cooling method and power derating refer to typical characteristic curves.